DC 6V To 30V One Way Relay Module Delay Power Off Disconnection Trigger Delay Cycle Timing Circuit Switch (1)
DC 6V To 30V One Way Relay Module Delay Power Off Disconnection Trigger Delay Cycle Timing Circuit Switch (2)

Sell DC 6V To 30V One Way Relay Module Delay Power Off Disconnection Trigger Delay Cycle Timing Circuit Switch best price

0
ratings
SGD 3.73
Ships from
Mainland China

Product Description

DC 6V To 30V One Way Relay Module Delay Power Off Disconnection Trigger Delay Cycle Timing Circuit Switch 1. The wide voltage supply (6-30 V) supports a 5 V micro USB power supply, which is very convenient to use; 2. Emergency stop function with one button (Stop key), with reverse polarity protection, the reverse connection does not burn; 3. sleep mode added, enabled, without operation in 5 minutes, automatically turn off the monitor; any key is activated; 4. You can set different parameters OP, CL, LOP, these parameters are independent of each other, respectively, saved; 5. All configuration parameters will be saved and saved automatically. Parameters: Size: 3.8 6.2 * 1.7 cm (length * width * height) Operating voltage: DC 6 V-30 V (supports 5 V micro USB power supply) Trigger signal source: high level trigger (3 V-24 V) ground signal and system to improve the anti-interference capability of the system (also short circuit) Output capacity: you can control the device within 30V DC 5A or within AC 220V 5A Standstill current: 20mA Operating current: 50mA Shelf life: 100,000 times Operating temperature: -40 ° C-85 ° C With optocoupler isolation, improved anti-interference capability, industrial-grade circuit board, it sets parameters for memory after power failure. How to configure parameters: 1. First determine the operating mode of the relay; 2 according to the operation mode of the relay, in the main interface (when the module is on, the current operating mode will flash (P1.1 default mode), and then enter the main interface,) ""press and hold the SET button for 2 seconds to release it. "" Enter the mode selection interface, select the mode to be configured (P1.1 ~ P-4) by pressing the up and down keys; 3 after selecting the mode to be configured (for example, P3.2), press the set button to configure the corresponding parameter and the parameter to be configured will flash (OP driving time, CL cut-off time, LOP cycle times (""- ""On behalf of the infinite number of cycles), through the top, Adjusts the value of the parameter, supports long presses (fast increase or decrease) and short presses (increases or decreases 1 Unit), after setting the parameter value, press STOP key shortly to select the position of the decimal point, select the time range (the corresponding time is 0.1 seconds and 999 minutes); Press the SET button to set the next parameter of the current mode, the process is the same as the previous one; 4. After setting the parameters of the selected mode, press and hold the SET button for 2 seconds to release it. The current configuration mode will flash and then return to the main interface. The configuration of the parameters is correct. Main interface: ""000"" (without decimal point) is displayed when the relay does not work. The relay is in the operating state with a decimal point;

From the same shop

Related items

You may also like