(Brand New)12V T2302 Timing Delay Relay Module Cycle Timer Digital LED Dual Display (1)
(Brand New)12V T2302 Timing Delay Relay Module Cycle Timer Digital LED Dual Display (2)
(Brand New)12V T2302 Timing Delay Relay Module Cycle Timer Digital LED Dual Display (3)
(Brand New)12V T2302 Timing Delay Relay Module Cycle Timer Digital LED Dual Display (4)
(Brand New)12V T2302 Timing Delay Relay Module Cycle Timer Digital LED Dual Display (5)
(Brand New)12V T2302 Timing Delay Relay Module Cycle Timer Digital LED Dual Display (6)
(Brand New)12V T2302 Timing Delay Relay Module Cycle Timer Digital LED Dual Display (7)

Sell (Brand New)12V T2302 Timing Delay Relay Module Cycle Timer Digital LED Dual Display best price

0
ratings
SGD 11.71
53% OFF
SGD 5.56
Ships from
Mainland China

Product Description

Specifications: Working voltage: DC 12V(5V/24V over 100pcs can be customized) Relay: 20A Timing range: 0-999 seconds, 0-999 minutes, 0-999 hours Working mode: delay on, delay off, timing on, timing off, cycle on, cycle off Size: 45.5mm*26.5mm*30mm/1.79*1.04*1.18" Weight: 25g Product Instructions: Please pay attention for your first use. You need wait 6s after your setting data, the module will save the date you have set after 6s. Short press button SET: If you start the time setting mode , Nixie tube will blink. You could adjust the time T1 and T2 by button+ and button-. Please wait 5s after your setting date, the module will save the date you have set after 5s . Long press button SET: if you start the parameter setting mode. There are two group parameter for your choice : P0 and P1. You could switch P0 or P1 by short press SET. Under the parameter P0 and P1,you could set the timing mode by the button+ and button-. P0--0: Timing time mode : 0---999s. P0--1: Timing time mode : 0---999min. P0--2: Timing time mode : 0---999h. P1--0: The relay will connect after you delay the T1 time . P1--1: The relay will disconnect after you delay the T1 time. P1--2: The relay will connect after you delay the T1 time first, Then the relay will disconnect after you delay the T2 time , it finish. P1--3: The relay will disconnect after you delay the T1 time first, Then the relay will connect after you delay the T2 time , it finish. P1--4: The relay will connect after you delay the T1 time first, Then the relay will disconnect after you delay the T2 time , it is cyclic. P1--5: The relay will disconnect after you delay the T1 time first, Then the relay will connect after you delay the T2 time , it cyclic. Example: A customer needs 10 seconds to start up and 20 seconds off. Setup is as follows: T1 set time 10, T2 set time 20 P0 -- 0 (T1 time range is seconds) P1--5 (timer work mode) Included: 1 xT2302 Time Digital Relay

Product Specifications

Safety Mark

From the same shop

Related items

You may also like